[解除]3/22 14:47臺北主節點TP-NCS2K-Core、TP-NCS2K-Metro設備出現 Signal Loss on Data Interface狀況。(恢復時間: 3/24 13:48)
從 星期六, 23 3月 2019
到 星期日, 24 3月 2019

國網中心於3/22 14:47 監控到TP-NCS2K-Core、TP-NCS2K-Metro設備出現 Signal Loss

on Data Interface狀況

TP-NCS2K-Core、TP-NCS2K-Metro出現多筆介面異常狀況,影響多筆TANet電路流量。補充如下, 

事件開始時間        事件結束時間        設備名稱        事件描述

2019/3/23 14:50     持續中    TANet-TP-ASR9912-01    [TANet-TRTC-ASR9010-02_Ten0/5/1/0] in:0 Mbps out:0 Mbps

2019/3/23 14:50     持續中    TANet-TP-ASR9912-01    [TANet-TRTC-ASR9010-02_Hun0/0/0/0] in:0 Mbps out:0 Mbps

2019/3/23 14:50     持續中    TANet-TP-ASR9912-01    [TANet-NDHU-ASR9010-01_Hun0/0/0/0] in:0 Mbps out:0 Mbps

2019/3/23 14:50     持續中    TANet-TP-ASR9912-01    [TANet-NTU-ASR9912-01_Hun0/0/0/0] in:0 Mbps out:0 Mbps

2019/3/23 14:50     持續中    TANet-TP-ASR9912-01    [TANet-NCCU-ASR9010-01_Hun0/0/0/0] in:0 Mbps out:0 Mbps

2019/3/23 14:50     持續中    TANet-TP-ASR9912-01    [TANet-SINICA-ASR9010-01_Hun0/0/0/0] in:0 Mbps out:0 Mbps

2019/3/23 14:50     持續中    TANet-TP-ASR9912-01    [TANet-TN-ASR9912-01_Hun0/0/0/2] in:0 Mbps out:0 Mbps

2019/3/23 14:50     持續中    TANet-TP-ASR9912-01    [TANet-HC-ASR9912-01_Hun0/0/0/1] in:0 Mbps out:0 Mbps

2019/3/23 14:55     持續中    TANet-TP-ASR9912-01    Backbone Circuit Interface(Ten0/9/0/6) Abnormal (TANet-TRTC-ASR9010-02_Ten0/5/1/0)

2019/3/23 14:55     持續中    TANet-TP-ASR9912-01    Backbone Circuit Interface(Hun0/0/0/7) Abnormal (TANet-TRTC-ASR9010-02_Hun0/0/0/0)

2019/3/23 14:55     持續中    TANet-TP-ASR9912-01    Backbone Circuit Interface(Hun0/0/0/6) Abnormal (TANet-NDHU-ASR9010-01_Hun0/0/0/0)

2019/3/23 14:55     持續中    TANet-TP-ASR9912-01    Backbone Circuit Interface(Hun0/0/0/3) Abnormal (TANet-NTU-ASR9912-01_Hun0/0/0/0)

2019/3/23 14:55     持續中    TANet-TP-ASR9912-01    Backbone Circuit Interface(Hun0/0/0/4) Abnormal (TANet-NCCU-ASR9010-01_Hun0/0/0/0)

2019/3/23 14:55     持續中    TANet-TP-ASR9912-01    Backbone Circuit Interface(Hun0/0/0/5) Abnormal (TANet-SINICA-ASR9010-01_Hun0/0/0/0)

2019/3/23 14:55     持續中    TANet-TP-ASR9912-01    Backbone Circuit Interface(Hun0/0/0/2) Abnormal (TANet-TN-ASR9912-01_Hun0/0/0/2)

2019/3/23 14:55     持續中    TANet-TP-ASR9912-01    Backbone Circuit Interface(Hun0/0/0/1) Abnormal (TANet-HC-ASR9912-01_Hun0/0/0/1)

====================================================

3/24 TA-TP-ASR9912-01有出現供電電流過低Log,將ASR所有卡板拔除後再重新一片一片插回,恢復正常